Technical Parameters: (1)Rated voltage(KV): -HSIS solid insulated ring main cabinet:12 kv -HSIS(C) load-break switch:12 kv -HSIS(V) circuit breaker:12 kv -Composite apparatus:12 kv -HSIS disconnecting,grounding switch:12kv (2)Rated current (A): -HSIS solid insulated ring main cabinet:630/1250 -HSIS(C) load-break switch:630/1250 -HSIS(V) circuit breaker:630/1250 -Composite apparatus:125 -HSIS disconnecting,grounding switch:630/1250 (3)Rated frequency(Hz): -HSIS solid insulated ring main cabinet:50 -HSIS(C) load-break switch:50 -HSIS(V) circuit breaker:50 -Composite apparatus:50 -HSIS disconnecting,grounding switch:50 (4)Operation types: -HSIS solid insulated ring main cabinet:Vaccum -HSIS(C) load-break switch:Vaccum -HSIS(V) circuit breaker:Vaccum -Composite apparatus:Vaccum -HSIS disconnecting,grounding switch:Vaccum (5)Arc extinguishing types: Permanent magnet and spring
Request for a quoteChina
-Rated voltage :10KV -Rated insulation voltage:690V -1min power-frequency withstand voltage:2500V -Rated current:100A,200A,250A,315A,400A,500A,630A -Rated short-circuit breaking current :16、31.5、40、50kA -Shell protection level: IP33
Request for a quoteChina
The technical parameters: -Rated voltage:12KV -Rated current :690V -1min power-frequency withstand voltage:42KV -Thermostabilization current:15-50KA -Dynamic stability current:40-125KA -Lighting impulse withstand voltage:75-105KV
Request for a quoteChina
-Rated voltage:12KV -Rated current:690V -1min power-frequency withstand voltage:42KV -Thermostabilization current:15-50KA -Dynamic stability current:40-125KA -Lighting impulse withstand voltage:75-105KV
Request for a quoteChina
(1)Switchgear technical parameters: -Rated voltage:3、6、10 kv -Rated insulation level: *power-frequency withstand voltage (1min):42 KV *lightning impulse:75KV -Rated frequency:50HZ -Main busbar rated current:630、1250、1600、2000、2500、3150、4000A -4s thermostabilization current(effective value):16、20、25、31.5、40、50KA -Rated Dynamic stability current(peak value):40、50、63、80、100、125KA -IP:The outer shell is IP4X, The isolation room and breaker are IP2X (2)Vacuum Circuit-breaker Parameter: -Rated Voltage:10KV -Rated Frequency:50HZ -Rated Current :630-4000A -Rated short-circuit breaking current:15-50 KA -Rated short-circuit current:40~125KA -Rated thermostabilization current(valid values) :15~50KA -Rated thermostabilization current(peak value):40~125KA -Breaking times of Rated short-circuit breaking current 100 times -Rated Operating Sequence:off-0.3s-on off-180s-on/ off -power-frequency withstand voltage:42(lmin) KV
Request for a quoteChina
1Rated Voltage :12kV 2Rated Current :630/1250A 3Rated Frequency :50Hz 4Rated short-circuit breaking current :25kA 5Breaking times of Rated short-circuit breaking current :30Times 6Rated peak with stand current:63kA 7Rated short-time withstand current(4S):25kA 8Rated short-circuit current:63kA 91 min power-frequency withstand voltage 1min :42/48kV 10lightning impulse withstand voltage:75/85kV 11Mechanical service life: -10000 Times(Spring) -30000 Times(Permanent Magnetic) 12Rated operation order opening-0.3s-closing and opening -180s- closing and opening 13Switch weight:150Kg
Request for a quoteChina
1Rated Voltage :12kV 2Rated Current :630/1250A 3Rated Frequency :50Hz 4Rated short-circuit breaking current :25kA 5Breaking times of Rated short-circuit breaking current :30Times 6Rated peak with stand current:63kA 7Rated short-time withstand current(4S):25kA 8Rated short-circuit current:63kA 91 min power-frequency withstand voltage 1min :42/48kV 10lightning impulse withstand voltage:75/85kV 11Mechanical service life: -10000 Times(Spring) -30000 Times(Permanent Magnetic) 12Rated operation order opening-0.3s-closing and opening -180s- closing and opening 13Switch weight:150Kg
Request for a quoteChina
1Rated Voltage :12kV 2Rated Current :630A 3Rated Frequency :50Hz 4Rated short-circuit breaking current :25kA 5Breaking times of Rated short-circuit breaking current :30Times 6Rated peak with stand current:63kA 7Rated short-time withstand current(4S):25kA 8Rated short-circuit current:63kA 91 min power-frequency withstand voltage 1min :42/48kV 10lightning impulse withstand voltage:75/85kV 11Mechanical service life: -10000 Times(Spring) -30000 Times(Permanent Magnetic) 12Rated operation order opening-0.3s-closing and opening -180s- closing and opening 13Switch weight:150Kg
Request for a quoteChina
(1)Rated voltage(KV): -HSIS Solid insulated ring main cabinet:12 -HSIS(C) load-break switch:12 -HSIS(V) circuit breaker:12 -composite apparatus :12 (2)Rated current (A): -HSIS Solid insulated ring main cabinet:630/1250 -HSIS(C) load-break switch:630/1250 -HSIS(V) circuit breaker:630/1250 -composite apparatus :630/1250 (3)Rated frequency(Hz):50 (4)Operation types:vacuum (5)Arc extinguishing types :Permanent magnet and spring /Spring (6)Power-frequency withstand voltage(KV):42/48 (7)Lighting impulse(KV):75/85 (8)Rated short-circuit breaking current (KA):20 (9)Rated short-circuit breaking current Breaking times :30 (10)Rated short-circuit current (KA):50/20 (11)Rated short –circuit breaking current breaking times:5/2 (12)Rated short-time withstand current :20 (13)duration of rated short-circuit:4
Request for a quoteChina
Technical parameters: -Rated voltage:12KV -Rated frequency:50HZ -Rated current(the main bus bar):630A -Rated current short-term tolerance:20/4 or 25/2 (kA/s) -Rated peak when the current tolerance:50KA -Rated short-circuit making current:50KA -Rated active load breaking current:630A -Rated closed loop breaking current:630A -Rated breaking load transformer capacity:1600KVA -Rated cable charging current:10A -Rated short-circuit breaking current:31.5KA -Rated transfer current:3150A -Power frequency withstand voltage (min):phase-phase and phase-ground: 42A; isolation break:48A -Lightning shock pressure:phase-phase and phase-ground: 75KA; isolation break: 85KA
Request for a quoteManufacturer/ Producer
Room 609, Building 3, No.16, Nansanhuan West Road, Fengtai District
100068 Beijing - China
Turkey
Lighting Busbar Trunking (25A) E-Line KY-S Lighting Busbar Trunking Systems has been designed for buildings and industrial facilitieswhich have lighting and outlet circuits with diminutive electrical machinery and equipment that needs three phase and/or single phase energy requirements with 25A.KY-S Lighting Busbar with its 10A – 16 A tap-off plugs and 32A tap-off boxes are being manufactured by fully automated machines that uses the latest technology in accordance with ISO 9001 and with its quality assurance system certification. Products have been designed in accordance with IEC 61439-6 and tested. Busbar housing are manufactured as pre-galvanized sheets, additionally if requested, it could be manufactured applying RAL 7038 colour.
Request for a quoteTurkey
Installation accessories are standard materials which are necessary to use for the mounting of the cable management systems and supporting accessories.Available finishes for our fixing accessories are Electro galvanized, Lacquered and Stainless Steel products.
Request for a quoteTurkey
EAE Seismic Support Systems offer rigid solutions for installations that require earthquake protection. The seismic supports, which can be utilized in any type of installation, allows for quick and easy installation due to the accessories that are designed for steel beam and space roof connections.
Request for a quoteTurkey
EAE with over 46 years of experience in manufacturing, design and marketing. Without comprising on service and quality the transition to Solar Power applications was done with ease. The company is equipped to perform specific design and manufacturing, for domestic and international projects which embrace new ventures in renewable energy from start to finish.
Request for a quoteCreate one request and get multiple quotes form verified suppliers.